top of page

NOAH

COMING 
SOON

Tissue Oximetry System

The Small Sensor to Make a Big Difference

OxyPrem's non adhesive sensor is a solution that is specifically designed for the smallest patients with the clinical need in mind: simple to use, reusable, and affordable to hospitals worldwide. 

Sensor designed specifically for your smallest patients 

Using 10+ wavelengths of light and a dynamic calibration approach, our advanced technology maximises robust signal processing while minimising surface signal contamination to ensure reliable and accurate continuous monitoring. 

Advanced algorithms
preterm neonate of 970 g with OxyPrem NOAH sensor

NOAH uses liquid phantom validation, a progressive benchmark approach which was recently included within the international safety and performance standards for cerebral oximetry monitors.

This approach enables reproducible validation over a broad range of oxygenation and haemodynamic states of neonatal physiology. 

Gold Standard validation 

NOAH provides a high quality, accessible and cost-effective solution to support routine standard monitoring in critical care worldwide. 

Cost effective, accessible continuous monitoring 

Publications

Quantifying the effect of adipose tissue in muscle

We measured StO2 of a liquid phantom by 3 continuous wave (CW) oximeters (Sensmart Model X-100 Universal Oximetry System, INVOS 5100C, and OxyPrem v1.3), as well as a frequency-domain oximeter, OxiplexTS, through superficial layers with 4 different thicknesses

In vivo precision assessment in neonates

We estimated the precision of the OxyPrem tissue oximeter to be ≤ 1.85 %.

Comparison of tissue oximeters on a liquid phantom (extension)

We evaluated the NIRS oximeters FORE-SIGHT, NIRO and SenSmart, and reproduced previous results with the INVOS and OxyPrem v1.3 oximeters.

Comparison of tissue oximeters on a liquid phantom

We made a blood-lipid phantom simulating the neonatal head to determine the relation between oxygenation values obtained by different oximeters.

OxyPrem 1.4 tissue oximetry system

OxyPrem 1.4.

Used in hospitals from 11 countries. Learn more about our first product.
The self-calibrating, non-adhesive sensor is gently placed on the patient. To keep it in place, it can be positioned underneath the CPAP cap or be attached with a bandage.
tissue oximetry illustration

Reusable and Trustworthy

NOAH is a neonatal specific, next-generation NIRS monitoring system that uses a high-precision reusable sensor to provide real-time, continuous tissue oximetry which you can trust. 

Testimonials

What clinicians say about us and OxyPrem NOAH.
Head of the NICU
Swiss NICU

“OxyPrem AG shapes their products with great determination towards the real needs and harsh realities of neonatal intensive care units.”

Owner and CEO,
international medical device distribution
company

“The great benefit behind the OxyPrem probe is its reusable design.”

Chief Neonatologist
Spanish NICU

“…monitor is simple to use and gives easily to interpret information.”

Deputy Head Department of Neonatology
Polish NICU

“…What makes the sensor unique is that it is designed for multiple use.”

Deputy Head Division of Neonatology
Austrian NICU

“…high precision is of high importance for any future clinical application.“

Head of the NICU
Belgian NICU

“…certainly superior to the current systems on the market.”

bottom of page